2021 Newest Intelligent Portable Coating Thickness Gauge Paint Film Coating Thickness Gauge

5.0 Sets
MOQ
2021 Newest Intelligent Portable Coating Thickness Gauge Paint Film Coating Thickness Gauge
Features Gallery Product Description Request A Quote
Features
Specifications
Warranty: 1 Years
Customized Support: OEM
Model Number: CT2021FN
Product Name: Coating Thickness Gauge
Measuring Principle:: Magnetic Induction (F-probe) And Eddy Current (N-probe);
Measuring Range:: 0 To 3000um (0 To 118mils);
Um Accuracy:: ± (3% Of Readings+2um);
Mils Accuracy:: ± (3% Of Readings+0.078mils);
Application: Coating Thickness Measurement
Keyword: Paint Thickness Gauge
OEM/ODM: Workable
Certification: CE ISO9001
MOQ: 5set
Basic Infomation
Certification: CE ISO9001
Model Number: CT2021FN
Payment & Shipping Terms
Packaging Details: 1 piece of one glass box, including one gauge , one set of film thickness (50/100/250/500um) , two susbrates of iron and alu , 1 piece of user manual
Supply Ability: 1000 Set/Sets per Month
Product Description
Product Description
  • Product Description:

The coating thickness measuring instrument uses a dual function measurement method, it can automatically identify magnetic and
non-magnetic substrate, and then use the appropriate test method, it can measure the thickness of the non-magnetic coating (such
as aluminum, copper, enamel, rubber, paint, etc) on magnetic metal substrates (such as steel, iron , alloy and Hard magnetic
steel). And the non-conductive coating thickness on a non-magnetic metal substrate.
The instrument has advantages of high detection accuracy, reliable and easy to maintain, good stability, simple operation, etc. 
Product Usage
    • Product usage introduction

产品使用方式介绍
Coating thickness gauge could be widely used for  auto industry , shipbuilding industry ,metalworking industry, and so on .
  • Description of product use effect

产品使用效果说明
Using our coating thickness gauge could get more information of the car paint, and found out whether the car has some serious accident before .
Related Products
Packing&Shipping
Packaging & Shipping:
1 complete set of gauge package: 1 pcs gauge, 1 set calibration, 1 instruction, 1 black glasses box.
Company Introduction
Pulani - A professional upcoming trading company which has own manufactory and Super post-doctoral R&D team . R&D- the key to the success of Pulani. Quality - the starting point Culture of Company: Honesty,Innovation,Passion
FAQ
1) How the coating thickness gauge shut down?
A: Our coating thickness gauge adopt with automatic shutdown, when you stop using it, it will be shutdown automatic after 30 seconds.
2) What angle should be kept with Coating thickness with the substrate ?
A: The probe must be kept perpendicular to the surface with the measured material, otherwise it will lead to considerable error.
3) How to maintain accuracy of measurement when we need repeatedly measurements ?
A: When we need repeatedly measure, the thickness gauge should be keep the distance more than 3cm away from the substrate and at least keep 2 seconds or more interval .(Attention :Do not drag along the surface to the side of the probe to avoid probe magnetization.it will be impact of next measurement result)
4) When should we to calibrate the Coating thickness ?
A: Our thickness gauge has been calibrated , in most time, we just need to check whether the uncoated substrate is normalized to
zero .Usually when the measurement accuracy beyond the precision values ,it need to be calibrated (refer to the instructions
precision value range) . Calibration method according to operating instructions.
5) When the Coating thickness display with"" ,What does it mean?
A: It indicates that the battery voltage is low, please replace the battery in the automatic shutdown, otherwise it will affect
the measurement accuracy.
6) How to choose the zero substrate?
A: The thickness of zero substrate should be used as the test material to avoid the permeability of different materials and
measurement errors.
7) How to choose the zero substrate surface?
A: Use the gauge should be in the same part of the material being tested after calibrating to zero, and then measuring the same
part. If the measuring pipe, bar and other curve surface materials, but the user indeed calibrating to zero with substrate of
flats surface , this will affect the accuracy of the measurement. And choose the calibrating zero surface should be more smooth.
8) Coating thickness gauge has been calibrated, why also the measurement also not accurately?
A: The coating thickness calibration could not choose the substrate random ,firstly calibrating to zero based on the same test
material of substrate which without coating , then put the calibration sheet in the top to calibrate, so that could get reliable
measurement data. Remember: Be sure to use the same shape, the same material, the same roughness zeroing calibration substrate.
9) Why the different coating thickness measured data is not the same?
A: Due to different coating thickness gauge calibrated with different substrate before use . For consistency, we should make them in the same uncoated substrate to do the zero calibration, and then put the calibration sheet in the top to calibrate, so
different coating thickness measurement data will be keep consistent.
10) When should we to replace to Standard film ?
A: The coating thickness calibration depends on the calibration sheet, so it is very important that keep the calibration sheet in
good condition. If the calibration sheet has been used for many years and not in a good condition, please replace it . Otherwise,
the measurement data will be inaccurate.

Semi-Automatic PET Bottle Blowing Machine Bottle Making Machine Bottle Moulding Machine PET Bottle Making Machine is suitable for producing PET plastic containers and bottles in all shapes.

Title goes here.

Semi-Automatic PET Bottle Blowing Machine Bottle Making Machine Bottle Moulding Machine PET Bottle Making Machine is suitable for producing PET plastic containers and bottles in all shapes.
Recommended Products
Get in touch with us
Contact Person : Bella
Characters Remaining(20/3000)